  "checked_on": "2026-11-25",
  "references": [
    {
      "title": "Hydro-Pac LX nitrogen capacity chart",
      "url": "https://www.hydropac.com/literature/LX%20Capacity%20Chart%20N2%20scfm%2010-2008.pdf",
      "use": "Manufacturer sizing reference, not a confirmed assembled-station curve."
    },
    {
      "title": "Hydro-Pac cylinder filling",
      "url": "https://www.hydropac.com/cylinder-filling.html",
      "use": "Manufacturer scope and compressor cooling."
    },
    {
      "title": "ASTM E2930-26 pressure decay reference",
      "url": "https://store.astm.org/e2930-26.html",
      "use": "Sensitivity and dwell design reference. Summary uses ideal gas and excludes deformable vessels. No direct compliance claimed for HP-A."
    },
    {
      "title": "Span nitrogen EOS (NIST)",
      "url": "https://www.nist.gov/publications/reference-equation-state-thermodynamic-properties-nitrogen-temperatures-63151-1000-k",
      "use": "Real-gas property reference to be validated with vessel compliance and temperature measurement."
    },
    {
      "title": "ISO 24431:2016",
      "url": "https://www.iso.org/standard/63063.html",
      "use": "Transportable cylinders; actual applicability requires classification."
    },
    {
      "title": "ISO 11755:2005",
      "url": "https://www.iso.org/standard/35969.html",
      "use": "Transportable cylinder bundles; actual applicability requires classification."
    }
  ]
}