{
  "status": "CONDITIONAL_IDEAL_NOZZLE_NO_JT_PHASE_COUPLING",
  "reviewed_files": [
    {
      "path": "D:\\Codex_Outputs\\ARGON-Multisystem-Scenarios-R3-20261115\\work\\physics\\base_mujoco.py",
      "sha256_at_review": "bf17262101e403b7afd9d501330c340ce7e59a1f07f1e279aae52444f5537930"
    },
    {
      "path": "D:\\Codex_Outputs\\ARGON-Multisystem-Scenarios-R3-20261115\\work\\physics\\simulate_descent.py",
      "sha256_at_review": "3b17b39c6cc0206dce591c25705ee7bd0d4d8c1907279f7419ba9d00134b43f9"
    },
    {
      "path": "D:\\Codex_Outputs\\ARGON-Multisystem-Scenarios-R3-20261115\\work\\physics\\trace_contract.json",
      "sha256_at_review": "bc6e4e4277d7bb38b519d203a97af5f8f050520c39186332c5e2276a4384a9cd"
    },
    {
      "path": "D:\\Codex_Outputs\\ARGON-Multisystem-Scenarios-R3-20261115\\work\\physics\\run_r3.py",
      "sha256_at_review": "603356049b5fc68b013cb568bf722e2a6e6a615967cdbf8af74cbb2cfac4b789"
    }
  ],
  "implemented_at_review": [
    "CoolProp real-air, well-mixed adiabatic/isentrope tank lookup",
    "80 bar absolute remaining-tank pressure floor",
    "Finite 44 mm throat / 50 mm exit, twelve vertical outlets",
    "Momentum and exit pressure thrust term",
    "Assumed supply pressure head limit 0.8 times tank pressure",
    "Variable gas mass and rigid-body mass properties in inherited 6DOF model"
  ],
  "not_coupled": [
    "Isenthalpic feed/throttle cooling",
    "Heat transfer of tank, lines, valve and nozzle",
    "Moisture/ice deposition and material temperature qualification",
    "Phase-aware nozzle mass-flow and thrust",
    "Validated common-feed transient map or qualified CFD thrust curve"
  ],
  "aft_force_law_at_review": "Four aft ports use an explicit force-per-flow surrogate Ce=450*sqrt(Tbank/293.15) m/s; this is not a measured finite-area aft nozzle map.",
  "prior_screening": "Sealed R2 independent real-air screening found 24 of 274 sampled states outside its single-phase nozzle solution. This is not a failure probability and is not a trajectory-specific invalidity fraction.",
  "critical_interpretation": [
    "An 80 bar reserve floor is not a thermal-safe limit.",
    "Single-phase property failure must not be silently continued as a measured physical prediction.",
    "Real-air tank density alone does not validate an ideal-gamma nozzle force law.",
    "All linked stages must debit the same air bank.",
    "Suction acts only while the underbody can remain sealed to a surface; no upward AIR force in free flight.",
    "The published Tesla system description does not establish the performance of Argon."
  ],
  "next_validation": [
    "Replay each R3 time trace with p_tank,T_tank,p_nozzle through a phase-aware feed model.",
    "Measure or specify valve Cv, minimum passages, dead time and branch splits.",
    "Add thermal state/control limits and uncertainty on discharge coefficient.",
    "Use stand tests for thrust, mass flow, pressure and temperature before declaring flight feasible."
  ]
}