TextToCADРусский
C.400 P.2 · R6E3 3D · 15.11.2026

Atar 101D.V in operation

One active slot deflects the exhaust by 0.45° and changes the axial reaction by -223 N. Symmetric four-slot injection changes the axial reaction by -833 N and keeps the jet aligned.

C.400 P.2 · ATAR 101D.V · R6E3 3D

TextToCAD
Atar FreeCAD section
R6E1 engine section
Engine installed in C.400 P.2
C.400 P.2 · R6E1
InletC3 · bleedC7Turbine inletNozzle inlet

Switch modes, drag to rotate, and select an exit-plane field.

Download MP4 · 28 s · Sector A fields · ParaView · Four-slot fields · ParaView

Jet angle and thrust change

ModeInjection, kg/sAxial reaction, kNΔ vs closed, NJet angleAzimuthVs nominal
Closed0.00029.31+00.00°—+3.1%
A0.32929.08-2230.45°225°+2.3%
B0.32928.88-2240.48°315°+1.6%
C0.32928.88-2240.48°45°+1.6%
D0.32928.88-2240.48°135°+1.6%
A + B0.65928.67-4370.65°270°+0.8%
A + C0.65928.67-4380.00°—+0.8%
All four1.31828.47-8330.00°—+0.1%
A, higher bleed0.44228.81-2960.63°225°+1.3%
All, higher bleed1.76728.02-10860.00°—-1.5%
A, 6 mm slot0.32928.88-2210.47°225°+1.6%
A, all available bleed ‡1.75728.07-10312.44°225°-1.3%
R6E1 CAD, closed0.00044.24+00.00°—+55.5%
R6E1 CAD, A0.32944.01-2290.38°225°+54.7%

AAMS gives 2900 kgf for the engine and describes transverse injection from four slots. One slot deflects the jet. Four slots constrict it. About 4% refers to the total extraction including roll. Measured angles and thrust changes by setting are absent from that record. AAMS · 34–36

Simulation conditions

At the main operating point, C3 air enters at 360.2 K total temperature. The scenario allocates 75% of the 1.757 kg/s bleed budget to the sector manifold. An open branch receives one quarter of that allotment. The remainder covers potential roll use and air not directed into the nozzle. Main inlet total conditions are 195.45 kPa and 967.96 K, with 101.325 kPa ambient.

Full-circumference finite-volume Euler solution, HLLC, first-order space, pseudo-time RK2. Cartesian momentum, transported C3 mass fraction and caloric properties of the two mixing gases. Jet angle comes from the convective momentum integral at the exit. Axial reaction includes exit gauge pressure. Each reaction change uses the closed case on the same grid and at the same inlet conditions.

Sector dimensions are estimates. These runs omit the complete compressor, physical valves, viscous mixing and the plume outside the nozzle. The animation switches between steady solutions. † marks the iteration limit. ‡ marks required total pressure exceeding C3 supply before duct losses.

Verification and FeedBack

17 runs. Maximum mass and energy residuals 0.003% and 0.004%. The two grids put A at 0.476° and 0.452°. Four-slot axial change across these grids is -838 and -833 N.

FeedBack addendum · Acceptance · Summary CSV · Native CAD survey · Reproduction

M. Kadosch · transverse injection principle