C.400 P.2 · R6E4 · 15.11.2026
Atar 101D.V nozzle transients
After the sector A open command, the jet angle reaches 10% in 2.83 ms. After the close command it recovers by 90% in 4.47 ms. The synchronized four-slot case keeps the jet on axis.
MP4 video · 30 s · Response times and peaks · CSV · Time-series fields · ParaView
Delay and thrust response
Times are relative to the opening or closing command. t10 and t50 are the first crossings of 10% and 50% of the steady change. Recovery t90 is the first crossing of 90% of the return to closed. ΔF is the axial exit-plane reaction from momentum and gauge pressure.
The calculation shows the exit-plane reaction. During rapid switching, stored momentum changes also affect forces transmitted to engine mounts.
Sector A · 3 ms · CSV
Sector A · 9 ms · CSV
Four sectors · 3 ms · CSV
Setup and archive
Commands occur at 1 and 13 ms in the fast case, and at 1 and 25 ms in the slow case. Flow starts changing 2 ms after the command and reaches its new value over 3 or 9 ms. These are scenario inputs. Historical valve and duct dynamics remain unresolved. Conservative residuals do not measure rig-level accuracy.
AAMS documents third-stage bleed, solenoid valves and jet turning or symmetric constriction. The 28.44 kN figure is nominal whole-engine thrust. Transient validation requires bench traces of command, supply pressure and force components. AAMS · 34–36