# R10 ยท 2026-11-11 Modern engineering candidate for early XJ314; separate from RAE. New parts are ASSUMED. Preserves both Nene interiors and their bright palette. R9_METHOD_REFERENCE.md is a historical method reference, not an R10 receipt. Run run.ps1 SCRIPT (Python) or run.ps1 SCRIPT -Gui (independent hidden FreeCAD1.1.4). The runner defines legacy XJ314_R4 and parent/source paths; edit those paths if moving the release. Scripts require the released R9 parent and earlier R3/R3A helper modules. Use one writer per master and separate profiles. No installed TextToCAD code is changed. Order: build.FCMacro; audit9.py; kinematics9.py; passage9.py; thermal9.py; acoustic9.py; contact9.py; assess10.py; preview9.FCMacro; feedback.FCMacro; verify_native.FCMacro; docs10.py; report10.py. Legacy filenames are retained for the reused solvers. All summaries and QA carry the actual R10 master SHA. Fresh build computes its own mass and exports. Final seal10.py hashes every delivered payload and verifies the ZIP. R10 changes: spring wire1.1/meanD22mm/N7,preload2.5N;larger spring cups;seat crown R16mm;four0.9mm piston holes with four0.6mm progressive needles;one moving guard with48 holes of0.5mm. Proposed brazed piston/guard joints require process proof. Seven active helical turns do not define end-coil manufacture. G77GPa is held constant;stress is screened against a conservative borrowed718 yield bound,not a wire certificate. Protection limits: coarse guard is not a fine filter.0.5mm holes and0.1mm guard/rod bypass do not establish retention for0.15mm needle clearance. Particle shape,fibres,agglomeration,abrasion,cleaning/service access and complete blockage remain OPEN. Parallel-port and guard loss are represented by a series equivalent-area approximation;no intermediate compressible volume is solved. The guard displaced volume (order5%of minimum rear gas volume) and changed heat transfer are omitted. No declaration of contamination-safe operation. Thermal: same432-case original grid for R9/R10 comparison,81 bulk-clearance combinations;an extra432-case proposed-finish grid0.2/0.5/1um is an explicit process target,not measured. No thermal gradients are silently reduced. Remaining adverse cases stay OPEN. Same ideal-gas line/plenum source assumptions as R9. The new spring rate/preload and effective mass enter fresh dynamics. F/R failures and spatial/time refinement are retained. Contact uses an elastic plate and assumed damping0.15;Hertz uses new R16 crown. No local3D transient FEA,rough-contact plasticity or hot test. Positive thermal clearance is not sealing qualification. Reports RU/EN carry limits beside results. Colours are functional display colours. No aircraft build,flight,service-life or historical manufacturing approval follows from native FeedBack completion.