  "master_sha256": "2e32f3eac2f7bc533df93941daa81f3588b933e98990aee0805a4e68fa5e0af1",
  "bulk_cases": 81,
  "minimums_with_size_tolerances": {
    "guide_diametral_margin_mm": 0.018941000000000548,
    "piston_diametral_margin_mm": 0.21642260000000094,
    "ring_end_gap_mm": 0.6296014601181579,
    "ring_radial_compression_mm": 0.0571759999999999
  },
  "seal_cases": 432,
  "nominal": {
    "T_K": 650,
    "reverse_dp_kPa": 300.0,
    "rough_residual_um": 1.0,
    "azimuth_through_gradient_K": 2,
    "plate_stiffness_factor": 1,
    "thermal_waviness_amplitude_um": 6.644833333333333,
    "approach_um": 44.28888493199811,
    "loaded_arc_fraction": 1.0,
    "max_residual_gap_um": 1.0,
    "air_leak_g_s": 0.0007429287240918133,
    "target_0_1_g_s_pass": true,
    "load_residual_N": 0.0
  },
  "refined": {
    "T_K": 650,
    "reverse_dp_kPa": 300.0,
    "rough_residual_um": 1.0,
    "azimuth_through_gradient_K": 2,
    "plate_stiffness_factor": 1,
    "thermal_waviness_amplitude_um": 6.644833333333333,
    "approach_um": 44.28888493199812,
    "loaded_arc_fraction": 1.0,
    "max_residual_gap_um": 1.0,
    "air_leak_g_s": 0.0007429287239880216,
    "target_0_1_g_s_pass": true,
    "load_residual_N": 1.1368683772161603e-13
  },
  "refinement_leak_difference_g_s": 1.0379175817420982e-13,
  "failed_seal_cases": 128,
  "worst_sealing": {
    "T_K": 293,
    "reverse_dp_kPa": 300.0,
    "rough_residual_um": 3.0,
    "azimuth_through_gradient_K": 30,
    "plate_stiffness_factor": 2,
    "thermal_waviness_amplitude_um": 71.67249999999999,
    "approach_um": 59.28794325172971,
    "loaded_arc_fraction": 0.4375,
    "max_residual_gap_um": 87.05705674827027,
    "air_leak_g_s": 5.699140403880055,
    "target_0_1_g_s_pass": false,
    "load_residual_N": 1.1368683772161603e-13
  },
  "assumed_leak_target_g_s": 0.1,
  "scope": "718 bulk alpha14.5e-6/K envelope; four independent part temperatures293/500/650K. Nominal assembled lap gap1.2mm, free-ring OD32.3mm. Sector elastic plate foundation brackets stiffness0.5/1/2; assumed 3-lobe warp and residual rough gaps. Crown Reynolds resistance capped by slot sonic flow. Positive bulk clearance does not establish hot sealing or ring friction. No coupled 3D thermal/contact FEA, asperity closure, creep or measured leakage."
}