Four0.9mm ports,four0.6mm needles;guard48×0.5mm holes. Free area9.425mm2 versus meter2.545mm2. Cases cover one blocked port,three blocked ports plus50% guard blockage,and95% guard blockage.
Protection is coarse and conditional. Particles below0.5mm pass;guard rod clearance0.1mm;needle clearance0.15mm. Fibres,flakes and agglomeration require tests. Complete obstruction is not qualified.
Two series resistances use an approximate equivalent area;guard displaced volume and heat transfer are omitted.
XJ314 · R10 · ENGINEERING
Springs and impact
Parameter
R9
R10
Wire/mean diameter,mm
0.9 /18
1.1 /22
Preload,N
2
2.5
Rate,N/mm
0.1546875
0.18906
Torsion,MPa
280.31
231.848
Margin to assumed allowable
1.089
1.316
Minimum hot turn gap,mm
-
0.309
G77GPa;7active turns;full-lift force and Wahl correction recalculated. Yield792.9MPa is a borrowed conservative718 screen;factor1.5 and shear criterion. Wire certificate,end coils,relaxation and fatigue remain OPEN.
Impact uses an elastic plate and assumed contact damping0.15. Hertz ring contact usesR16;local3D contact strength is not validated.
Native FeedBack and STEP are checked again. Dynamics uses uniform2.4m pipes without a measured compressor map. Numerical convergence does not establish physical accuracy.
Next:3D thermal/contact seat model,hot-leak and dirty-dashpot tests,piston/guard joint qualification and spring fatigue. Historical drawings and weight sheet remain open.